welding is not permitted.
解釋: 啟動(dòng)焊接信號(hào)后無接觸信號(hào),導(dǎo)致無法焊接文章源自好焊孫輝博客 http://www.4863x.com好焊孫輝-http://www.4863x.com/weldgyzb/autoweld20241129.html
Cause: ? No stud in collet.文章源自好焊孫輝博客 http://www.4863x.com好焊孫輝-http://www.4863x.com/weldgyzb/autoweld20241129.html
原因:? 夾套里沒有焊釘文章源自好焊孫輝博客 http://www.4863x.com好焊孫輝-http://www.4863x.com/weldgyzb/autoweld20241129.html
- Feeder without weld studs.
送料器里沒有焊釘文章源自好焊孫輝博客 http://www.4863x.com好焊孫輝-http://www.4863x.com/weldgyzb/autoweld20241129.html
- Stabilizer incorrectly set or contaminated.
支撐腳或噴嘴調(diào)整不當(dāng)或太臟文章源自好焊孫輝博客 http://www.4863x.com好焊孫輝-http://www.4863x.com/weldgyzb/autoweld20241129.html
- Weld circuit interrupted.
焊接回路中斷文章源自好焊孫輝博客 http://www.4863x.com好焊孫輝-http://www.4863x.com/weldgyzb/autoweld20241129.html
- Weld head fault (i.e. weld head got jammed).
焊頭故障(例如:焊頭被卡住了)文章源自好焊孫輝博客 http://www.4863x.com好焊孫輝-http://www.4863x.com/weldgyzb/autoweld20241129.html
- Collet defective.
夾持器損壞了文章源自好焊孫輝博客 http://www.4863x.com好焊孫輝-http://www.4863x.com/weldgyzb/autoweld20241129.html
Remedy: ? Remove loading fault.文章源自好焊孫輝博客 http://www.4863x.com好焊孫輝-http://www.4863x.com/weldgyzb/autoweld20241129.html
措施: 排除送釘故障文章源自好焊孫輝博客 http://www.4863x.com好焊孫輝-http://www.4863x.com/weldgyzb/autoweld20241129.html
- Check adjusting of stabilizer.
檢查支撐腳或噴嘴的調(diào)整狀態(tài)
- Check welding circuit.
檢查焊接回路
- Stud feeding.
送一次釘
- Repeat weld cycle.
重復(fù)一次焊接
- Replace collet.
更換夾持器
- Notify service engineer!
專業(yè)人員處理
?????????????????????????????????????????????????????????? ?????????????????????????????????????????????????????????????
Fault 3: “Weld tool not in back position“
故障?3?:焊頭沒有在焊接位置
Explanation: Proximity switch for back position not configured, defective or power supply missing.
解釋:焊接位置的接近開關(guān)沒有被蓋住或接近開關(guān)被損壞或者沒有電壓
Cause: ? Drop in compressed-air supply.
原因: 壓縮空氣供應(yīng)氣壓不足
- Cable package defective.
管線總成損壞
- Monitoring time after welding was exceeded.
焊接之后的檢測(cè)時(shí)間超差
- Weld head defective.
焊頭損壞
- Feeder defective.
送料器損壞
- Collet welded to work surface.
把夾持器焊在工件表面了
Remedy: ? Check compressed air.
措施:? 檢查壓縮空氣供應(yīng)裝置
- Check cable package.
檢查管線總成
- Check weld head - slide rail motion.
檢查焊頭運(yùn)動(dòng)滑軌
- Check or replace weld head.
檢查或更換焊頭
- Check feeder.
檢查送料器
- Check feeder fuses F1-F3.
檢查送料器保險(xiǎn)絲F1-F3
- Reset fault.
故障復(fù)位
- Replace collet.
更換夾持器
- Notify service engineer!
專業(yè)人員處理
?????????????????????????????????????????????????????????????????
Fault 5: “Weld procedure sequence fault“
故障?5?:焊接程序順序故障
Explanation: Due to a malfunction the weld sequence is not terminated correctly.
解釋:由于一個(gè)錯(cuò)誤功能使焊接過程沒有按照程序進(jìn)行到底
Cause: ? Feeder or SMPS malfunction.
原因:? 送料器或電源故障
Remedy: ? Reset fault.
措施:? 故障復(fù)位
- Check welding (if necessary repeat welding).
檢查焊接(重新焊接)
- Notify service engineer!
專業(yè)人員處理
???????????????????????????????????????????????????????????????????????? ???????????????????????????????????????????????
Fault 6: “Program no selected“
故障?6?:?缺少程序
Explanation: The weld unit does not detect any program number.
解釋: 焊接單元不識(shí)別程序號(hào)碼
Cause: ? Program no. is 0.
原因: 程序號(hào)碼為0
- Transfer signal has not been set.
沒有設(shè)置接受信號(hào)
- Data line defective.
數(shù)據(jù)線被損壞了
Remedy: ? Customer interface (or interface program) must be verified.
措施: 檢查用戶接口(或接口程序)是否編寫
- Notify service engineer!
專業(yè)人員處理
??????????????????????????????????????????????????????????????????????????????????????????????????????? ???????????????
Fault 7: “Program not active“
故障?7?:?程序沒有激活
Explanation: The selected weld program is not active and therefore cannot be executed.
解釋: 由于被選擇的焊接程序沒有被激活,因此無法實(shí)施焊接
Cause: ? Weld unit incorrectly programmed.
原因: 焊接單元程序編寫錯(cuò)誤
- Fault customer control.
用戶控制端錯(cuò)誤
- Data line defective.
數(shù)據(jù)線被損壞了
Remedy: ? Check weld program and activate or select an active weld program.
措施:? 檢查焊接程序并激活或者選擇一個(gè)已經(jīng)激活的程序
- Notify service engineer!
專業(yè)人員處理
????????????????????????????????????????????????????
Fault 13: “SMPS: Lift fault“
故障?13?:???電源:沒有拉弧
Explanation: Weld unit is unable to identify lift via measurement lines.
解釋:焊機(jī)通過它的測(cè)量線不能確定拉弧過程
Cause: ? Incorrectly sequence of lift movement.
原因: 拉弧過程的順序不正確
- Weld conditions prohibit lift.
焊接條件阻礙了拉弧
- Cable package defective.
管線總成損壞
- Weld head defective.
焊頭被損壞
- Defective feeder.
送料器被損壞
- Internal process cycle fault.
設(shè)備內(nèi)部運(yùn)行故障
Remedy: ? Check weld conditions.
措施: 檢查焊接條件
- Check weld head.
檢查焊頭
- Check feeder.
檢查送料器
- Stud feeding.
送一次釘
- Check feeder connection.
檢查送料器連接線
- Repeat weld cycle.
重復(fù)一次焊接
- Forced WC.
啟動(dòng)焊接完成信號(hào)
- Notify service engineer!
專業(yè)人員處理
???????????????????????????????????????????????????????????
Fault 15: “Drop down timeout“
故障?15?:?下落時(shí)間超時(shí)
Explanation: Max. drop time was exceeded and welding was stopped.
解釋: 下落時(shí)間超出最大允許值,焊接被中斷
Cause: ? Air gap incorrectly adjusted.
原因: 間隙調(diào)整錯(cuò)誤
- Weld circuit resistance too high.
焊接回路電阻過高
- Measurement line-ground missing.
沒有連接地線測(cè)量線
- SKK / PK defective.
自動(dòng)焊頭或焊槍損壞
Remedy: ? Reset fault.
措施: 故障復(fù)位
- check measurement line (if necessary, reduce weld circuit resistance)
檢查測(cè)量線(降低焊接回路電阻值)
- Check setting of SKK- / PK.
檢查自動(dòng)焊頭或焊槍狀態(tài)
- Notify service engineer!
專業(yè)人員處理
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
Fault 16: “Open circuit, no arc“
故障?16?:?空載焊接
Explanation: Extinguishing of the arc during weld, resp. the weld current is below I =80A.
解釋: 焊接過程中拉弧被斷開,或焊接回路電流小于80A
Cause: ? Air gap too large.
原因: 間隙過大
- Gun was removed at the beginning of the weld.
焊槍在開始焊接時(shí)被提起
- Extremely impure work surface.
焊接表面油污太多
- Fault SMPS.
電源故障
Remedy: ? Repeat weld cycle.
措施: 重復(fù)一次焊接
- Stud feeding.
送一次釘
- Check adjusting of the weld gun.
檢查焊槍的調(diào)整
- Check welding conditions.
檢查焊接條件
- Check work piece conditions.
檢查工件表面
- Notify service engineer!
專業(yè)人員處理
????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
Fault 17: “Measurement line broken“
故障?17?:?測(cè)量線中斷
Explanation: Measurement line signal not any longer detected.
解釋: 測(cè)量線信號(hào)沒有被捕捉到
Cause: ? Measurement line broken or incorrectly connected.
原因: 測(cè)量線損壞或連接錯(cuò)誤
- Reversed measurement line-ground and measurement line.
地線測(cè)量線和測(cè)量線接反了
- SOW power failure.
和工件的接觸電壓中斷
- Weld line interrupted.
焊接電纜中斷
博主現(xiàn)就職于深圳市鴻栢科技實(shí)業(yè)有限公司, 從事焊接設(shè)備營(yíng)銷推廣及銷售工作15年,擁有豐富的行業(yè)經(jīng)驗(yàn)及資源,致力于中國汽車焊接設(shè)備營(yíng)銷推廣,歡迎廣大汽車制造焊接工藝與車身新材料連接技術(shù)研究的朋友們一起探討新技術(shù)、新設(shè)備。??
? ? ? ?螺柱焊機(jī),點(diǎn)焊機(jī),電極帽修磨機(jī)及各種焊接設(shè)備備件易損件,備件采購聯(lián)系:18682260315
AI賦能螺柱焊接系統(tǒng):多模態(tài)感知、動(dòng)態(tài)優(yōu)化與自主決策的范式革新